Specifications |
Manufacturer |
FLUKE |
Meter type |
digital multimeter |
Type of display used |
LCD 3,75 digit (6000) |
DC voltage measuring range |
1m...6/60/600V |
DC voltage measuring accuracy |
(0,5% + 2 digits) |
Resistance measuring range |
0,1...600/6k/60kΩ |
Resistance measuring accuracy |
(0,9% + 2 digits) |
Capacitance measuring range |
1n...1000n/10΅/100΅/9999΅F |
Capacitance measuring accuracy |
(1,9% + 2 digits) |
Diode test |
1,2mA, 2,7V |
Continuity test |
acoustic signal for R<20Ω |
Pollution degree |
2 |
Overall dimensions (W x D x H) |
84 x 46 x 167mm |
Weight with battery |
404g |
Power supply |
1 battery 9V 6F22 |
Conform to the norm |
EN61010 600V CAT III |
Important information |
FLK-C25 FREE |
|
Measuring instrument features:
- auto and manual ranging
- automatic power-off
- large, backlit LCD
- HOLD function
- MIN/MAX/MEDIUM function
- low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK)
- impact resistant holster
- measures true RMS AC
- diode and continuity test with buzzer
- removable holster
- low battery indicator
|
Standard equipment:
- battery
- FLK-TL75 test leads
|
|