| Specifications |
| Manufacturer | FLUKE |
| Type of meter | digital multimeter |
| Kind of display used | LCD |
| Display parameters | 3,75 digit (6000) |
| Bargraph | 33 segm. 40x/s |
| DC voltage measuring accuracy | ±(0.09% + 2 digit) |
| AC voltage measuring accuracy | ±(1% + 3 digit) |
| DC current measuring accuracy | ±(1% + 3 digit) |
| AC current measuring accuracy | ±(1.5% + 3 digit) |
| True effective value measurement | True RMS AC |
| Capacitance measuring accuracy | ±(1.2%+ 2 digit) |
| Frequency measuring accuracy | ±(0.1%+1 digit) |
| Resistance measuring accuracy | ±(0.9%+1 digit) |
| Diode test | 1.1mA @2.4V |
| Weight with battery | 420g |
| Power supply | battery 6LR61 9V x1 |
| Standard equipment | FLK-TL75 test leads |
| Dimensions (W x H x D) | 89x190x45mm |
| Battery/ rechargeable battery | battery 6LR61 9V x1 |
| Manufacturer series | Fluke 170 |
| Measurement | AC current, AC voltage, capacitance, DC current, DC voltage, frequency, resistance |
| Continuity test | acoustic indication, <25Ω |
| Optional equipment | - 400A AC/DC FLK-I410 current clamp probe
- FLK-C90 soft cover
- FLK-TLK220 set
|
| Measuring instrument features | - auto and manual ranging
- dangerous voltage alarm (over 30V)
- HOLD function
- impact resistant holster
- indicates incorrect connection of test leads
- low battery indicator
- MIN/MAX/MEDIUM function
- settable standby mode
- smoothing mode that enables to filter quick changing input signals
|
|