Specifications |
Manufacturer |
FLUKE |
Meter type |
digital multimeter |
Type of display used |
LCD 3,75 digit (6000) |
Bargraph |
33 segm. 32x/s |
DC voltage measuring range |
0,1m...600m/6/60/600V |
DC voltage measuring accuracy |
(0,5% + 2 digits) |
AC voltage measuring range |
0,1m...600m/6/60/600V |
AC voltage measuring accuracy |
(1% + 3 digits) |
DC current measuring range |
0,1µ...600µA |
DC current measuring accuracy |
(1% + 2 digits) |
AC current measuring range |
0,1µ...600µA |
AC current measuring accuracy |
(1,5% + 3 digits) |
Resistance measuring range |
0,1...600/6k/60k/600k/6M/40MÙ |
Resistance measuring accuracy |
(0,9% + 1 digit) |
Capacitance measuring range |
1n...1000n/10µ/100µ/9999µF |
Capacitance measuring accuracy |
(1,9% + 2 digits) |
Frequency measuring range |
0,01...99,99/999,9/9,999k/50kHz |
Frequency measuring accuracy |
(0,1% + 2 digits) |
Temperature measuring range |
40...400°C |
Temperature measurement accuracy |
(0,1% + 2 digits) |
Diode test |
1,2mA, 2,7V |
Continuity test |
acoustic signal for R<20Ù |
Pollution degree |
2 |
Overall dimensions (W x D x H) |
84 x 46 x 167mm |
Weight with battery |
550g |
Power supply |
1 battery 9V 6F22 |
Conform to the norm |
EN61010 600V CAT III |
Important information |
FLK-C25 FREE |
|
Measuring instrument features:
- auto and manual ranging
- automatic AC/DC voltage selection (AutoVolt)
- large, backlit LCD with bargraph
- HOLD function
- MIN/MAX/MEDIUM function
- low input impedance function (LoZ)
- measures frequency, capacitance and temperature
- measures microamperes for testing flame sensors
- measures true RMS AC
- diode and continuity test with buzzer
- removable holster
- low battery indicator
|
Standard equipment:
- battery
- FLK-TL75 test leads
|
Optional equipment:
- Set of FLK-MC6 clothes
- FLK-C50 soft cover
- FLK-TOOLPAK strap with magnet for suspending the meter
|
|