Specifications |
Manufacturer |
AXIOMET |
Meter type |
insulation resistance meter |
Type of display used |
LCD |
Sampling |
2,5x/s |
Test voltage |
1000VDC (for range 1M...4000MΩ), 125VDC (for range 0.125M...4000MΩ), 250VDC (for range 0.25M...4000MΩ), 500VDC (for range 0.5M...4000MΩ) |
Resistance measuring range |
0,01...40/400Ω |
Resistance measuring accuracy |
(1,2% + 3 digits) |
Insulation resistance measuring ranges |
0,125M...4M/40M/400M/4000MΩ |
Insulation resistance measuring accuracy |
(2% + 10 digits) |
AC voltage measuring range |
1...750V |
AC voltage measuring accuracy |
(1,2%+ 10 digits) |
DC voltage measuring range |
1...1000V |
DC voltage measuring accuracy |
(0,8% + 3 digits) |
Continuity test |
acoustic signal for R<35Ω |
Pollution degree |
2 |
Operating temperature |
0...40°C |
Storage temperature |
10...60°C |
Body dimensions |
200 x 92 x 50mm |
Weight with battery |
700g |
Power supply |
6 batteries 1,5V LR6 (AA) |
Conform to the norm |
EN61010 1000V CAT III |
|
Measuring instrument features:
- autoranging
- automatic power-off
- bargraph
- large double backlit LCD
- HOLD function
- MIN/MAX function
- impact resistant holster
- continuity test with buzzer
- overvoltage protection
- measurement voltage blocking
- display zeroing function
- low battery indicator
|
Standard equipment:
- documentation
- test leads
- plastic case
|
|